Strata CIX Programming Guidelines
Use Default Auto-programming to Start Up
Strata CIX Programming Vol.1 12/09
1-5
St
ra
ta
C
IX
Pr
og
ram
m
in
g
The destination of Program 318, No Calling Party Number (CPN) and Out Of Search [for] DID number, is
assigned to the first Primary DN of the system (200 or 2000) in the all system operating modes (Day1,Day
2 and Night).
The DIT line (Ground and Loop) destinations of all trunks which generated automatically are set as the first
PDN 200 or 2000 depending on the system size – see Table 1-4.
ISDN PRI
2
5
DID – no default DID numbers
REMU analog E&M
3
6
Non-Strata Net
1. The line number is assigned to all lines in the numerical order according to the line PCB cabinet placements. Example:
Line number 1 will be on the first circuit of the line PCB placed in the lowest cabinet/slot number.
2. OLG:1 is created even if there is are no analog line PCBs installed.
Table 1-5
Auto-Programming of Miscellaneous Line Parameters
Item
Settings
DIT line ringing assignment
Program 310
All of the ringing destinations of DIT lines are the first PDN:
PDN 200 for CIX100, CIX200 and Basic Proc CIX670 (1~2 cab), CIX1200 Basic
PDN2000 for Expanded Processor CIX670. (3~7 cabinets), CIX1200 Expanded
DID numbers - not assigned
Program 309
The destination of DID is not assigned. DID numbers and ringing destinations
must be assigned manually from Strata eManager or the programming
telephone.
Format setting for DIT (T1)
Zero Code Suppress = B8ZS, Frame Format = ESF
Setting for CAMA / E911
The destination of internal notification is the first DN 200 or 2000 in the all
operation mode (Day1, Day2 and Night).
Setting for ISDN BRI CO
Common D channel is not assigned. One channel group is assigned to each
BRI PCB installed. The channel group number is assigned to each BRI interface
in the order in which the BRI PCBs are installed. The destination of DID is not
assigned.
Setting for ISDN PRI CO
Common D channel is not assigned. One channel group is assigned to each
PRI PCB installed. The channel group number is assigned to each PRI interface
in the order in which the PRI PCBs are installed. The destination of DID is not
assigned.
Setting for E&M Tie lines
The node number and the other setting for networking are not assigned
automatically.
Table 1-4
Auto-Programming of Line Groups and Service Types (continued)
CO line type
OLG
Prog 306
ILG
Prog 304
CO Service Type
Summary of Contents for CIX 200
Page 42: ...Network eManager 2 4 Strata CIX Programming Vol 1 12 09 ...
Page 43: ...Network eManager Strata CIX Programming Vol 1 12 09 2 5 Network eManager ...
Page 44: ...Network eManager 2 6 Strata CIX Programming Vol 1 12 09 ...
Page 314: ...This page is intentionally left blank ...
Page 432: ...This page is intentionally left blank ...
Page 434: ...This page is intentionally left blank ...