18 Night Bell Relay
Assign BIOU Relay (1~8) as the Night Relay - this relay activates when the
system is in the Night Mode.
BIOU1 provides relays 1 to 4.
BIOU2 provides relays 5 to 8
Note
The CIX100 ACTU and CIX200 LCTU built-in relay is
programmed as relay 5. For this relay operation, a virtual
BIOU2 is installed, as default, in a virtual equipment position
- Cabinet 2 slot 5. (Cab. 02 slot 05, PCB code 20, in prog.
100)
To install an actual BIOU2 and disable the ACTU built-in
relay, use the programming telephone to remove the virtual
BIOU2 and then install the actual BIOU2 in Cab. 01/slot
01~08 in the normal manner.
19 Display Preference
Select whether to display DNIS or Caller ID.
Possible values:DNIS (default) or Caller ID
20 Transit Counter
Select the Networking Transit Counter. This device limits the number of
nodes through which a Strata Net call can pass before being terminated as
a lost call.
Possible values:0~128 (default = 1)
21 Primary Clock
22 Secondary Clock
Enter data as xxyyzz. (xx = cabinet, yy = slot, zz = channel)
zz=channel 01 if clock source is RPTU or RDTU
zz=channel 01, 02, 03, or 04 if clock source is RBUU/RBUS or RBSU
Example: If the Primary Clock Source should be assigned to an RPTU in
Cabinet 5, slot 2, enter 050201.
Cabinet numbers:
CIX100 and CIX200: Select 01 for Base and Expansion cabinet.
CIX670: Select 01 for Base and 02~07 for Expansion cabinets.
CIX1200: Select 01 for Base and 02~12 for Expansion cabinets
Slot numbers:
CIX100: Select 01~04 for Base slots and 05~08 for Expansion slots.
CIX200: Select 01~03 for Base slots and 01~04 for Expansion slots.
CIX670: Select 01~08 for Base slots and 01~10 for Expansion slots.
CIX1200: Select 01~08 for Base slots and 01~10 for Expansion slots
23 Call History Prefix 1
Add the dialing prefix
1
when using the callback feature in Call History.
Possible values:Add (default) or Do Not Add
24 Emergency Digits
Sent
Enter an alternative emergency dialing string. If no value is entered in this
field any previously programmed value is overwritten.
Possible values:Up to 5 digits (default = 911)
25 DP Make Ratio
Select the Dial Pulse Make/Break ratio.
Possible values:33% (default) or 40%
F
IELD
D
ESCRIPTION
Summary of Contents for CIX 200
Page 42: ...Network eManager 2 4 Strata CIX Programming Vol 1 12 09 ...
Page 43: ...Network eManager Strata CIX Programming Vol 1 12 09 2 5 Network eManager ...
Page 44: ...Network eManager 2 6 Strata CIX Programming Vol 1 12 09 ...
Page 314: ...This page is intentionally left blank ...
Page 432: ...This page is intentionally left blank ...
Page 434: ...This page is intentionally left blank ...