Data Backup and Restore
Local Update
14-8
Strata CIX Programming Vol.1 12/09
Step 3: Update CIX100 Software
CAUTION!
This operation will take the system out of service for 10 minutes to an hour or more
depending on the CIX database.
1.
Insert the SmartMedia card containing PROGRAM\nhs.prg file into the Strata CIX processor
SmartMedia socket.
2.
From the programming telephone enter Program 911, and press Hold. Press FB01 and dial 1
(UPDATE) and then press Hold.
CAUTION!
Pressing Hold
twice will cause the Update to fail
After a short pause the CIX will begin to upload the software from the SmartMedia card to the processor
flash RAM causing the following:
•
If FB07-LED is flashing green, it indicates that the Update process is in progress.
•
If FB07-LED is flashing red, it indicates an error. This could be caused by a corrupt or incorrect
nhs.prg file or a defective SmartMedia card. Make sure the file is a CIX100 nhs.prg file and not
CIX670 or CIX1200 file.
•
You can now check the Update progress using FB02 (Total) and FB03 (Copied) to view data block
status. Periodically switch between FB02 and FB03 to view the data blocks.
•
When all the data blocks are copied the CIX stops normal processing and all telephone LCDs go
blank.
•
The processor Heartbeat LED is on steady red.
•
The processor SmartMedia LED turns on flashing rapidly at first, then flashes slowly and finally
stops flashing.
•
The above will last about five to 10 minutes.
•
When the Update is complete the system begins to operate normally with default data.
3.
Use Program 901
to check that the new software version of CIX software has been loaded. If you
cannot enter the Program Mode the new software may still be loading.
4.
Remove the SmartMedia card (which contains PROGRAM/nhs.prg file) from the CIX processor.
Step 4: Restart and Restore Strata CIX100 Backup Data
1.
Insert the SmartMedia labeled “Strata CIX Backup data” which you previously made at the start of this
procedure. This card contains PROGDATA/default.dat file.
2.
From the programming telephone enter Program 900.
Press
FB01
and dial
1
(ALL DATA CLEAR) and
then press
Hold
(twice). The Strata CIX will restart (initialize) on the new software and restore the
backed up program data. The time required for this operation will vary from a few minutes to 30
minutes or more depending on the size of the database.
Summary of Contents for CIX 200
Page 42: ...Network eManager 2 4 Strata CIX Programming Vol 1 12 09 ...
Page 43: ...Network eManager Strata CIX Programming Vol 1 12 09 2 5 Network eManager ...
Page 44: ...Network eManager 2 6 Strata CIX Programming Vol 1 12 09 ...
Page 314: ...This page is intentionally left blank ...
Page 432: ...This page is intentionally left blank ...
Page 434: ...This page is intentionally left blank ...