System
Dial Number Plan
4-12
Strata CIX Programming Vol.1 12/09
104 System Timer
Prerequisite Program:
None
This command assigns the system timers. System timers set a variety of times to control calls and features
for the Strata CIX.
1. In Network eManager, click System > System Timer.
2. Select the desired timer value for each of the fields.
3.
Get
Default
sets all values to factory default.
4. Click
Submit
.
F
IELD
D
ESCRIPTION
01 ACB Callback Timer
The Automatic Callback timer sets the time that Automatic Callback will wait
for Ring Back Tone being cancelled.
Possible values:5~180 sec. (default = 30)
02 ACB Cancel Recall
Timer
Select the ACB overall timer value. This value establishes a time limit for
the destination telephone number to become available. Once the timer
expires, the callback will be cancelled.
Possible values:5~180 min. (default = 30)
03 Park Recall Timer
Select the Park timer value. This sets the length of time a call can remain in
Park.
Possible values:10~600 sec. (default = 120)
04 Camp-on Timer
Select Camp-on timer value. This sets the time needed to remain off-hook
prior to Camp-on being automatically activated.
Possible values:5~15 sec. (default = 10)
05 SMDR Valid Call
Timer
The length of time that a call should be active before being captured by
SMDR. The SMDR Answer timer sets a default time for when an outgoing
call will be considered to be answered for SMDR reporting when a true
answer signal is not returned from the public network. Setting the time too
short will include calls that may not be completed, setting the time too long
may exclude short calls that are answered and terminated in a short time.
Possible values:0~180 sec. (default = 10)
06 Tandem Timer #1
Select timer for a trunk-to-trunk connection for which neither CO line has
release supervision, a timer is needed to release the call if no user
monitoring has taken place.
Possible values:0~3600 sec. (default = 300)
07 Tandem Timer #2
Provides the time to enable an external user to dial a digit to extend the
disconnect time when the connection is unsupervised. This feature is used
primarily with DISA.
Possible values:0~180 (default = 30)
08 CF No Answer Time
The System Call Forward No Answer timer specifies the time period that a
phone will ring prior to invoking the Call Forward operation.
Possible values:1~180 sec. (default = 30)
Summary of Contents for CIX 200
Page 42: ...Network eManager 2 4 Strata CIX Programming Vol 1 12 09 ...
Page 43: ...Network eManager Strata CIX Programming Vol 1 12 09 2 5 Network eManager ...
Page 44: ...Network eManager 2 6 Strata CIX Programming Vol 1 12 09 ...
Page 314: ...This page is intentionally left blank ...
Page 432: ...This page is intentionally left blank ...
Page 434: ...This page is intentionally left blank ...