Trunks
6-14
Strata CIX Programming Vol.1 12/09
310 DIT Assignment
Prerequisite Program:
300
This program assigns DIT Number Analysis Table for DIT trunks. DIT trunks are ground and Loop start
trunks.
1. Select Trunk > Trunk Assignments, DIT tab.
2. Enter Trunk equipment number field. Enter Program 310 data.
•
List
–
to view a summary list of programmed trunks timers.
•
Copy
– to copy to trunk timer ports.
3. Click
Submit
.
F
IELD
D
ESCRIPTION
Line No.
Enter the trunk equipment number. Equipment numbers are required when
assigning a new trunk to the system. It can also be used to display the
equipment location of existing trunks.
Enter data as XXYYZZ:
•
XX=cabinet 01~12
•
YY=slot 01~10
•
ZZ=analog trunk circuit 01~08
or
•
ZZ=T1channel 01~24.
Example: If a line should be assigned to an RCOU in cabinet shelf 5, slot 2,
circuit 3, enter 050203.
Cabinet numbers:
•
CIX100: Base, Exp.01
•
CIX200: Base 01, Exp.02
•
CIX670: Base 01, Exp 02~07.
•
CIX1200: Base 01, Exp 02~12
Slot numbers:
•
CIX100: Base 01, Exp.05~08
•
CIX200: Base/Exp.01~04
•
CIX670/1200: Base 01~08
•
CIX670/1200: Exp.01~10
CTX28 and CIX40 assignments below are hard coded and cannot be changed.
01, 02 - 3 CO lines on motherboard - 28, 40 R1HW, 4 CO lines - 40 R2HW
01, 05 – GVMU - 28, GVPH - 40 R1HW, GIPx, MIPU or GCOCIH - 40 R2HW
01, 06 – GIPx, MIPU16 or GCOCIH - 40 R1HW, no card - 28, 40 R2HW
01, 08 - 3 CO lines on GCDU - 28, 40 R1HW and R2HW.
Summary of Contents for CIX 200
Page 42: ...Network eManager 2 4 Strata CIX Programming Vol 1 12 09 ...
Page 43: ...Network eManager Strata CIX Programming Vol 1 12 09 2 5 Network eManager ...
Page 44: ...Network eManager 2 6 Strata CIX Programming Vol 1 12 09 ...
Page 314: ...This page is intentionally left blank ...
Page 432: ...This page is intentionally left blank ...
Page 434: ...This page is intentionally left blank ...