IP Telephone Programming
IP Telephone Installation and Network Connection Setup
Strata CIX Programming Vol.1 12/09
8-7
IP T
e
le
phone
Pr
ogra
mming
05 TOS Precedence Type
If TOS is selected in 04 TOS Field Type select a packet priority level - where
Critical/ESP provides the highest and Routine provides the lowest priority.
If TOS is selected in 04 TOS Field Type make selections in TOS Delay, TOS
Throughput Delay, and TOS Reliability Type.
Possible values:Routine, Priority, Immediate, Flash, Flash Override, or Critical/
ESP (Default)
TOS Delay Type
If TOS is selected in 04 TOS Field Type select Normal for most cases
Possible values:Normal (Default) or Low
TOS Throughput Type
If TOS is selected in 04 TOS Field Type select Normal for most cases
Possible values:Normal (Default) or High
TOS Reliability Type
If TOS is selected in 04 TOS Field Type select Normal for most cases
Possible values:Normal (Default) or High
06 DSCP
If DSCP is selected in 04 TOS Field Type select a priority level from 0~63.
Possible values:0~63 (Default = 0)
07 IEEE802.1p
Enable IEEE802.1p priority control if voice packets on an Ethernet LAN should be
prioritized with priority tagging. Higher priority, time-critical BIPU\IPT voice traffic
can have preferential treatment when other traffic is running at best effort. If you
enable IEEE802.1p, select which priority level to use (Voice or Best Effort) in 08
IEEE802.1p Configuration on this screen. All Ethernet devices on the LAN
(routers, switches, etc., must support IEEE802.1p for this feature to work correctly.
Possible values:Enable or Disable (Default)
08 IEEE802.1p
Configuration
If 07 IEEE802.1p is enabled, select Voice priority for BIUP\IPT voice packets to be
tagged with the highest priority level.
Possible values:Best Effort or Voice (Default)
09 IP-CTX Identifier
Enter a CIX node ID if more than one CIX node is on the IP network. This can be
the same as the Strata Net node ID used for this system if it is in a Strata Net
network - but the two IDs are not related in software logic. This ID must match the
node 'number' programmed in the IP telephone.
Possible values:Up to 5 ASCII characters
10 Tail Length of Echo
Canceller
Enter 16ms if any IP telephone is set for a G729A codec (Prog 250-08) or if the
Strata Net IP network is set for G729A codecs (Prog 672-06). If all codecs are
G711, then 16ms or 32ms can be used - 32ms may reduce echo on a network that
only utilizes G711 codecs. Never set this parameter to 64ms.
Note
Setting G729A codec and 32 msec will reduce the number of channels
available from 16 to 12 or 32 to 24.
Possible values:16 (Default), 32 or 64MS
11 Gain Control of IPT
and BIPU
Set the Voice Quality Mode to control gain of IPTs and BIPUs.
Possible values:High (Default), Middle or Low
F
IELD
D
ESCRIPTION
Summary of Contents for CIX 200
Page 42: ...Network eManager 2 4 Strata CIX Programming Vol 1 12 09 ...
Page 43: ...Network eManager Strata CIX Programming Vol 1 12 09 2 5 Network eManager ...
Page 44: ...Network eManager 2 6 Strata CIX Programming Vol 1 12 09 ...
Page 314: ...This page is intentionally left blank ...
Page 432: ...This page is intentionally left blank ...
Page 434: ...This page is intentionally left blank ...