Operation
System Setup
Strata CIX Programming Vol.1 12/09
10-5
Oper
ation
908 Secure Digital and SmartMedia
This program enables you to format and perform file management tasks on a Secure Digital or SmartMedia
card while it is installed in the CIX processor. Secure Digital (SD) cards are required for ACTU3A (CIX100),
BCTU2A (CIX670) and HCTU1A (CIX1200) processor cards.
Select Maintenance > SM/DS Card.
Secure Digital or SmartMedia Card
The SD card is replacing the SmartMedia (SM) card for use as a removable, portable memory device. The
SD is physically smaller than the SM card while storage capacity is the same or greater.
Notes
•
32MB or 64MB must be used for Strata CIX maintenance functions.
•
The Strata CIX does not use Compact Flash or other similar types of small storage devices.
Functions
An SD or SM Card(s) is required for most of the important Strata CIX maintenance functions such as:
•
Saving (Backup) and re-loading the programmed database of a particular Strata CIX system.
•
Saving Event trace data files for troubleshooting problems.
•
Updating or upgrading the Strata CIX operating software version.
Note
The procedure below will refer to the SM/SD card. The same procedures are used for both the
SmartMedia and Secure Digital card.
Administration and Use
•
When the SM/SD card is used to perform one of its functions, it is installed in the SM/SD slot of the
Strata CIX processor. It must be first formatted for Strata CIX operation by running Forced Format
(Program 908). Using the PC to format the SM/SD card is not recommended.
•
The Strata CIX format will create five special folders. These folders and how to use them are explained
below and in Chapter 14–Data Backup and Restore.
1. Install the SM/SD Card into the SM/SD slot of the Strata CIX processor.
2. Select Maintenance > SM/SD Card.
3. Click one of the following:
•
Normal Format – creates any CIX SM/SD folder that does not exist already. Existing folders are not
overwritten by this procedure.
Time Adjustment
Defines the exact amount of time change. Default is one hour. The time
adjustment should not be long enough to cause a date change.
Change based on
Date and Time
DST change can be set two ways:
1. Day of the week: time will change based on the Month, Time and Day of the
week set in this program
2. Date: time will change base on the Date and Time set in this program
Default:
Day of the week
F
IELD
D
ESCRIPTION
Summary of Contents for CIX 200
Page 42: ...Network eManager 2 4 Strata CIX Programming Vol 1 12 09 ...
Page 43: ...Network eManager Strata CIX Programming Vol 1 12 09 2 5 Network eManager ...
Page 44: ...Network eManager 2 6 Strata CIX Programming Vol 1 12 09 ...
Page 314: ...This page is intentionally left blank ...
Page 432: ...This page is intentionally left blank ...
Page 434: ...This page is intentionally left blank ...