Synergy 100 MD Operator’s Manual (v7.2 MD-S100)
Transitions • 5–9
•
You can
not
initiate an Auto Transition or a Cut in the
Transition Control
group if the
Fader
is off its upper or lower limit.
Changing Auto Transition Rates
The rate at which an Auto Transition is run is set from the
System Control Group
. This value is in
video frames and varies in time according to the video format you are using. If you are operating at
60 Hz, a single video frame is 1/30th of a second, whereas, at 50 Hz, a single video frame is 1/25th of
a second. If you are using film, a video frame is 1/24th of a second.
Note that Transition Rates for MultiDSKs can only be set through the menu system. Refer to the
section “
Setting MultiDSK Sources and Transition Rates
” on page 7–35 for more information.
Use the following procedure to set the Auto Transition Rate:
1. Press the right
SEL
button repeatedly until
AUTO
is displayed in the
Mode
area. If you
want to adjust the
Fade to Black
rate, you would display
FADE
in the
Mode
area, and
for
DSK Dissolve
you would display
DSK
. The rest of the procedure is the same.
System Control Group
2. Use the
100
,
10
and
1
buttons to enter the desired Auto Transition rate, in frames,
between
1
and
999
. The new rate is automatically updated and appears in the display.
System Control Group
This completes the procedure for setting the Auto Transition Rate. The switcher will use this rate for
the next Auto Transition that is run.
Note
If the Trans Limit function was active during the transition, the
switcher will treat the point that the transition was stopped at as the
Trans Limit for that particular transition.
Note
There is no way to cancel or undo your changes. If you do not want to
keep your changes, you will have to follow the procedure to set the
original rate again.
Operating
Tip
If you press and hold one of the buttons, that value will reset back to
the beginning.
S Y S T E M C O N T R O L
EDIT
SEL
BACK
MENU
100
10
1
AUTO
1 2 0
S Y S T E M C O N T R O L
EDIT
SEL
BACK
MENU
100
10
1
AUTO
1 5 0
Summary of Contents for Synergy 100 MD
Page 1: ...Ross Video Limited Operator s Manual Software Issue 7 2 MD S100...
Page 10: ......
Page 50: ...2 10 Control Panel Introduction Synergy 100 MD Operator s Manual v7 2 MD S100...
Page 62: ...3 12 Using the Menu System Synergy 100 MD Operator s Manual v7 2 MD S100...
Page 80: ...4 18 Switcher Basics Synergy 100 MD Operator s Manual v7 2 MD S100...
Page 148: ...7 42 Keying Synergy 100 MD Operator s Manual v7 2 MD S100...
Page 182: ...10 12 Peripheral Control and More Synergy 100 MD Operator s Manual v7 2 MD S100...
Page 210: ...11 28 Global Store Synergy 100 MD Operator s Manual v7 2 MD S100...
Page 238: ...12 28 Squeeze Tease MD Basic Operation Synergy 100 MD Operator s Manual v7 2 MD S100...
Page 256: ...14 6 Advanced Positioning Synergy 100 MD Operator s Manual v7 2 MD S100...
Page 276: ...16 8 Preprocessor Effects Synergy 100 MD Operator s Manual v7 2 MD S100...
Page 316: ...17 40 Squeeze Tease MD Sequences and Wipes Synergy 100 MD Operator s Manual v7 2 MD S100...
Page 376: ...21 4 Appendix B Synergy Effects Synergy 100 MD Operator s Manual v7 2 MD S100...
Page 382: ...22 6 Appendix C Hotkeys Synergy 100 MD Operator s Manual v7 2 MD S100...
Page 386: ...GL 4 Glossary of Terms Synergy 100 MD Operator s Manual v7 2 MD S100...
Page 402: ...IX 16 Index Synergy 100 MD Operator s Manual v7 2 MD S100...