13–8 • Position/Crop Functions
Synergy 100 MD Operator’s Manual (v7.2 MD-S100)
Channel Aspect Ratio
The
Aspect
feature enables you to squeeze or stretch a channel image horizontally and/or vertically.
Use the following procedure to adjust the aspect values of a channel image:
1. Navigate to the
Position/Crop Menu
as follows:
•
Press
FLY KEY
in the
Effects Keyers Group
.
•
Press
MENU
to display the
Main Menu
.
•
Press
8. S&T MD
to display the
S&T MD Menu
.
•
Press
0. Position/Crop
to display the
Position/Crop Menu
.
2. Press
4. Aspect
to display the
Aspect Menu
.
Position/Crop — Aspect Menu
3. Adjust the size of the channel image as follows:
•
X-Aspect —
Use the
HUE
knob, or move the
Positioner
left
and
right
,
to
squeeze
or stretch the channel image horizontally.
•
Y-Aspect —
Use the
SAT
knob, or move the
Positioner
up
and
down
,
to squeeze or
stretch the channel image vertically.
•
Size —
Use the
LUM
knob, or twist the
Positioner
knob
clockwise
and
counter-clockwise
,
to squeeze or stretch the channel image in both directions at the
same time.
This completes the procedure for adjusting the aspect values of an channel image.
Note
This feature can be used on channels only, if you are working with an
object, the
Aspect
option will be unavailable.
Operating
Tip
You can use the
POSN
hotkey to display the
Position/Crop Menu
directly.
Note
If the effect is not
On
(not yet in use), you must press
4. Aspect
again, to toggle to effect
On
.
Operating
Tip
The Size function is independent of the X-Aspect and Y-Aspect. For
example, if you set the X-Aspect to 2.000, the Y-Aspect to 1.000 and
the Size to 2.000, the width of the channel image (X-Aspect) will be
quadrupled and the height (Y-Aspect) will be doubled.
Use positioner or Hue, Sat, Lum to modify
Position/Crop
1 2 U O1 O2 Key 1
0. Position
1. Rotation
2. Pivot Preset
3. Pivot Position
4. Aspect
On
5. Crop Horizontal
6. Crop Vertical
7. Transp.
8. Freeze
9. Adv. Positioning
Aspect X: 100%
Y: 100%
Size: 100%
Off
Off
Summary of Contents for Synergy 100 MD
Page 1: ...Ross Video Limited Operator s Manual Software Issue 7 2 MD S100...
Page 10: ......
Page 50: ...2 10 Control Panel Introduction Synergy 100 MD Operator s Manual v7 2 MD S100...
Page 62: ...3 12 Using the Menu System Synergy 100 MD Operator s Manual v7 2 MD S100...
Page 80: ...4 18 Switcher Basics Synergy 100 MD Operator s Manual v7 2 MD S100...
Page 148: ...7 42 Keying Synergy 100 MD Operator s Manual v7 2 MD S100...
Page 182: ...10 12 Peripheral Control and More Synergy 100 MD Operator s Manual v7 2 MD S100...
Page 210: ...11 28 Global Store Synergy 100 MD Operator s Manual v7 2 MD S100...
Page 238: ...12 28 Squeeze Tease MD Basic Operation Synergy 100 MD Operator s Manual v7 2 MD S100...
Page 256: ...14 6 Advanced Positioning Synergy 100 MD Operator s Manual v7 2 MD S100...
Page 276: ...16 8 Preprocessor Effects Synergy 100 MD Operator s Manual v7 2 MD S100...
Page 316: ...17 40 Squeeze Tease MD Sequences and Wipes Synergy 100 MD Operator s Manual v7 2 MD S100...
Page 376: ...21 4 Appendix B Synergy Effects Synergy 100 MD Operator s Manual v7 2 MD S100...
Page 382: ...22 6 Appendix C Hotkeys Synergy 100 MD Operator s Manual v7 2 MD S100...
Page 386: ...GL 4 Glossary of Terms Synergy 100 MD Operator s Manual v7 2 MD S100...
Page 402: ...IX 16 Index Synergy 100 MD Operator s Manual v7 2 MD S100...