![Rohde & Schwarz FSW13 User Manual Download Page 112](http://html.mh-extra.com/html/rohde-and-schwarz/fsw13/fsw13_user-manual_1477847112.webp)
Measurements
R&S
®
FSW
112
User Manual 1173.9411.02 ─ 19
Zero Span
A sweep in the time domain at the specified (center) frequency, i.e. the frequency span
is set to zero. The display shows the time on the x-axis and the signal level on the y-
axis, as on an oscilloscope. On the time axis, the grid lines correspond to 1/10 of the
current sweep time.
Use the general measurement settings to configure the measurement, e.g. via the
"Overview" (see
chapter 6, "Common Measurement Settings"
Most result evaluations can also be used for zero span measurements, although some
functions (e.g. markers) may work slightly differently and some may not be available. If
so, this will be indicated in the function descriptions (see
Remote command:
Ch Power ACLR
Measures the active channel or adjacent-channel power for one or more carrier sig-
nals, depending on the current measurement configuration, and opens a submenu to
configure the channel power measurement.
For details see
chapter 5.3, "Channel Power and Adjacent-Channel Power (ACLR)
Remote command:
CALC:MARK:FUNC:POW:SEL ACP
, see
Results:
CALC:MARK:FUNC:POW:RES? ACP
, see
chapter 11.5.3, "Measuring the Channel Power and ACLR"
C/N, C/No
Measures the carrier/noise ratio and opens a submenu to configure the measurement.
Measurements without (C/N) and measurements with reference to the bandwidth
(C/No) are possible.
Carrier/noise measurement is only possible in the frequency domain (span > 0).
For details see
chapter 5.4, "Carrier-to-Noise Measurements"
Remote command:
CALC:MARK:FUNC:POW:SEL CN | CN0
Results:
CALC:MARK:FUNC:POW:RES? CN | CN0
, see
chapter 11.5.4, "Measuring the Carrier-to-Noise Ratio"
Available Measurement Functions