Bit No.
Meaning
7
LIMit 8 FAIL
This bit is set if limit line 8 is violated.
8 to 14
Unused
15
This bit is always 0.
STATus:QUEStionable:LMARgin Register
This register contains information about the observance of limit margins.
A separate LMARgin register exists for each active channel and for each window.
It can be read using the commands
STATus:QUEStionable:LMARgin:CONDition?
and
STATus:QUEStionable:LMARgin[:EVENt]?
.
Table 10-13: Meaning of the bits used in the STATus:QUEStionable:LMARgin register
Bit No.
Meaning
0
LMARgin 1 FAIL
This bit is set if limit margin 1 is violated.
1
LMARgin 2 FAIL
This bit is set if limit margin 2 is violated.
2
LMARgin 3 FAIL
This bit is set if limit margin 3 is violated.
3
LMARgin 4 FAIL
This bit is set if limit margin 4 is violated.
4
LMARgin 5 FAIL
This bit is set if limit margin 5 is violated.
5
LMARgin 6 FAIL
This bit is set if limit margin 6 is violated.
6
LMARgin 7 FAIL
This bit is set if limit margin 7 is violated.
7
LMARgin 8 FAIL
This bit is set if limit margin 8 is violated.
8 to 14
Not used
15
This bit is always 0.
STATus:QUEStionable:POWer Register
The
STATus:QUEStionable:POWer
register contains information about possible
overload situations that may occur during operation of the R&S
FSW. A separate
power register exists for each active channel.
You can read out the register with