![Rohde & Schwarz FSW13 User Manual Download Page 958](http://html.mh-extra.com/html/rohde-and-schwarz/fsw13/fsw13_user-manual_1477847958.webp)
Remote Commands
R&S
®
FSW
958
User Manual 1173.9411.02 ─ 19
The correction values for the bandwidth and the log amplifier are taken into account in
the measurement.
Parameters:
<State>
ON | OFF
*RST:
OFF
Example:
CALC:DELT:FUNC:PNO ON
Switches on the phase-noise measurement with all delta mark-
ers.
CALC:DELT:FUNC:FIX:RPO:X 128 MHZ
Sets the frequency reference to 128 MHz.
CALC:DELT:FUNC:FIX:RPO:Y 30 DBM
Sets the reference level to +30 dBm
Manual operation:
See
"Phase Noise Measurement State"
See
"Switching All Phase Noise Measurements Off"
11.8.3.11
Band Power Marker
The following commands control the marker for band power measurements.
Using Markers
CALCulate<n>:MARKer<m>:FUNCtion:BPOWer:MODE
.................................................... 958
CALCulate<n>:MARKer<m>:FUNCtion:BPOWer:RESult?
..................................................958
CALCulate<n>:MARKer<m>:FUNCtion:BPOWer:SPAN
.....................................................959
CALCulate<n>:MARKer<m>:FUNCtion:BPOWer[:STATe]
..................................................959
CALCulate<n>:MARKer<m>:FUNCtion:BPOWer:MODE
<Mode>
This command selects the way the results for a band power marker are displayed.
Parameters:
<Mode>
POWer
Result is displayed as a power in dBm.
DENSity
Result is displayed as a density in dBm/Hz.
*RST:
POWer
Example:
CALC:MARK4:FUNC:BPOW:MODE DENS
Configures marker 4 to show the measurement results in
dBm/Hz.
Manual operation:
See
CALCulate<n>:MARKer<m>:FUNCtion:BPOWer:RESult?
This command queries the results of the band power measurement.
Analyzing Measurements (Basics)