![Rohde & Schwarz FSW13 User Manual Download Page 769](http://html.mh-extra.com/html/rohde-and-schwarz/fsw13/fsw13_user-manual_1477847769.webp)
Remote Commands
R&S
®
FSW
769
User Manual 1173.9411.02 ─ 19
[SENSe:]LIST:RANGe<range>[:FREQuency]:STARt
<Frequency>
This command defines the start frequency of a spurious emission measurement range.
Make sure to set an appropriate span. If you set a span that is
●
smaller than the span the sweep list covers, the R&S
FSW will not measure the
ranges that are outside the span - results may be invalid.
●
greater than the span the sweep list covers, the R&S
FSW will adjust the start fre-
quency of the first range and the stop frequency of the last range to the span
For more information see
chapter 5.7, "Spurious Emissions Measurement"
Suffix:
<range>
.
1..30
Selects the measurement range.
Parameters:
<Frequency>
Numeric value.
*RST:
-12.75 MHz (range 1), -2.515 MHz (range 2), 2.515
MHz (range 3)
Default unit: Hz
Manual operation:
See
[SENSe:]LIST:RANGe<range>[:FREQuency]:STOP
<Frequency>
This command defines the stop frequency of a spurious emission measurement range.
Make sure to set an appropriate span. If you set a span that is
●
smaller than the span the sweep list covers, the R&S
FSW will not measure the
ranges that are outside the span - results may be invalid.
●
greater than the span the sweep list covers, the R&S
FSW will adjust the start fre-
quency of the first range and the stop frequency of the last range to the span
For more information see
chapter 5.7, "Spurious Emissions Measurement"
Suffix:
<range>
.
1..30
Selects the measurement range.
Parameters:
<Frequency>
Numeric value.
*RST:
-2.52 MHz (range 1), 2.52 MHz (range 2), 250.0
MHz (range 3)
Default unit: Hz
Manual operation:
See
Configuring and Performing Measurements