![Rohde & Schwarz FSW13 User Manual Download Page 966](http://html.mh-extra.com/html/rohde-and-schwarz/fsw13/fsw13_user-manual_1477847966.webp)
Remote Commands
R&S
®
FSW
966
User Manual 1173.9411.02 ─ 19
Example:
CALC:MARK:FUNC:DEM:SEL FM
Manual operation:
See
CALCulate<n>:MARKer<m>:FUNCtion:DEModulation[:STATe]
<State>
This command turns the audio demodulator on and off when the measurement rea-
ches a marker position.
Parameters:
<State>
ON | OFF
*RST:
OFF
Example:
CALC:MARK3:FUNC:DEM ON
Switches on the demodulation for marker 3.
Manual operation:
See
[SENSe:]DEMod:SQUelch:LEVel
<Threshold>
This command defines the threshold for selective demodulation.
All signals below the threshold are not demodulated.
Parameters:
<Threshold>
Percentage of the display height.
Range:
0 to 100
*RST:
50
Example:
DEM:SQU:LEV 80
Sets the squelch level to 80% of the displayed signal.
Manual operation:
See
[SENSe:]DEMod:SQUelch[:STATe]
<State>
This command turns selective demodulation at the marker position on and off.
For selective demodulation, the R&S
FSW turns on a video trigger whose level corre-
ponds to the squelch level. Therefore it turns other triggers or gates off.
Parameters:
<State>
ON | OFF
*RST:
OFF
Example:
DEM:SQU ON
Signals below the level threshold are not sent to the audio out-
put.
Manual operation:
See
Analyzing Measurements (Basics)