Remote Commands
R&S
®
FSW
698
User Manual 1173.9411.02 ─ 19
Manual operation:
See
See
See
See
See
See
CALCulate<n>:MARKer<m>:FUNCtion:POWer:SELect
<MeasType>
This command selects a power measurement and turns the measurement on.
Parameters:
<MeasType>
ACPower | MCACpower
Adjacent channel leakage ratio (ACLR) aka adjacent channel
power or multicarrier adjacent channel.
The R&S
FSW performs the measurement on the trace selected
with
CPOWer
Channel power measurement with a single carrier.
The R&S
FSW performs the measurement on the trace selected
with
OBANdwidth | OBWidth
Occupied bandwidth measurement.
The R&S
FSW performs the measurement on the trace that
marker 1 is positioned on.
CN
Carrier-to-noise ratio measurement.
CN0
Carrier-to-noise ratio measurement referenced to 1
Hz band-
width
Manual operation:
See
See
See
See
See
CALCulate<n>:MARKer<m>:FUNCtion:POWer[:STATe]
<State>
This command turns a power measurement on and off.
You can select a particular power measurement with
.
Parameters:
<State>
ON | OFF
*RST:
OFF
Manual operation:
See
See
Configuring and Performing Measurements