Trouble locating and clearing procedures (continued) 1-317
DMS-100 Family NA100 Trouble Locating and Clearing Procedures Volume 2 of 2 LET0015 and up
Running a C7BERT
(continued)
17
Determine the purpose of the next step.
18
To activate a local loopback, type
>PMLOOP LOCON link_no
and press Enter.
where
link_no
is the number of the link you want to test (0 to 15)
19
If you perform a remote loopback, inform a person at the far-end office that
•
you will busy and deactivate the link, and
•
the person must busy and deactivate the link at their end
If the next step is to perform
Do
a local loopback
step 18
a remote loopback
step 19
a link fault sectionalization
step 67
If the response
Do
is
This command is not implemented
step 22
is
Link nn: Failed - PM not equipped
with 9X78DA or 9X78DB
step 22
is
Link 1: Failed - C7BERT already ac-
tive on this link
step 23
is
Link 1: Loopback Local on complet-
ed
step 30
is
Link 1: Failed - PMLOOP <Local> is
already active
step 48
is
Link 1: Failed - PMLOOP <Remote> is
already active
step 49
is
Link 1: Loopback Local on complet-
ed.
WARNING:
In DTE mode, the V.35
clock must be present for C7BERT to
pass
step 66
is other than listed here
step 66