1-628 Trouble locating and clearing procedures (continued)
297-8021-544 Standard 14.02 May 2001
Troubleshooting a customer-reported failure
No FRIU alarms
(continued)
6
To access the PM level of the MAP display, type
>MAPCI; MTC; PM
and press Enter.
7
To post the FRIU identified in step 4, type
>POST FRIU friu_no
and press Enter.
where
friu_no
is the FRIU number obtained in step 4
8
Perform the procedure
Clearing a PM FRIU critical alarm (on an LPP) in
Alarm and Performance Monitoring Procedures. Do not return to this
procedure.
9
Perform the procedure
Clearing a PM FRIU major alarm (on an LPP) in Alarm
and Performance Monitoring Procedures. Do not return to this procedure.
10
Perform the procedure
Clearing a PM FRIU minor alarm (on an LPP) in Alarm
and Performance Monitoring Procedures. Do not return to this procedure.
11
Determine from the MAP banner if any alarms are present under the PM
header.
12
Perform the correct alarm clearing procedures. Refer to
Alarm and
Performance Monitoring Procedures.
If the FRIU
Do
is
SysB
step 8
is
SysB (NA)
step 8
is
ManB
step 9
is
ManB (NA)
step 9
is
ISTb
step 10
is
ISTb (NA)
step 8
is
InSv (NA)
step 11
is
InSv
step 13
If alarms
Do
are present
step 12
are not present
step 13