1-634 Trouble locating and clearing procedures (continued)
297-8021-544 Standard 14.02 May 2001
Troubleshooting a customer-reported failure
No PM alarms
(continued)
Note: The FRIU number and channel assigned to this agent appear under
the CONNECT TO header in the MAP response. In the example, the FRIU
is 5 and the channel number is 7.
5
To return to the CI level of the MAP display, type
>QUIT
and press Enter.
6
To access the PM level of the MAP display, type
>MAPCI; MTC; PM
and press Enter.
7
To post the FRIU identified in step 4, type
POST FRIU friu_no
and press Enter.
where
friu_no
is the FRIU number obtained in step 4
8
Perform the procedure
Clearing a PM FRIU critical alarm (on an LPP) in
Alarm and Performance Monitoring Procedures. Do not return to this
procedure.
9
Perform the procedure
Clearing a PM FRIU major alarm (on an LPP) in Alarm
and Performance Monitoring Procedures. Do not return to this procedure.
10
Perform the procedure
Clearing a PM FRIU minor alarm (on an LPP) in Alarm
and Performance Monitoring Procedures. Do not return to this procedure.
If the FRIU
Do
is
SysB
step 8
is
SysB (NA)
step 8
is
ManB
step 9
is
ManB (NA)
step 9
is
ISTb
step 10
is
ISTb (NA)
step 8
is
InSv (NA)
step 11
is
InSv
step 11