1-386 Trouble locating and clearing procedures (continued)
297-8021-544 Standard 14.02 May 2001
Setting up the signaling link marginal performance report
(continued)
Setting up the signaling link marginal performance report
At the MAP terminal
1
To access the CM level of the MAP display, type
>MAPCI;MTC;CM
and press Enter.
2
Determine if the computing modules (CM) have a synchronized status.
3
To quit from the CM level of the MAP, type
>QUIT ALL
and press Enter.
4
To access table OFCVAR, type
>TABLE OFCVAR
and press Enter.
5
To position on the office parameter C7_SLMPR_ALARM_ON, type
>POSITION C7_SLMPR_ALARM_ON
and press Enter.
Example of a MAP response:
6
Determine the value of the office parameter.
7
To change the value of the field to Y, type
>CHANGE 2 Y
and press Enter.
Example of a MAP response:
8
To confirm the command, type
>Y
and press Enter.
Example of a MAP response:
If the value
Do
is Y
step 9
is N
step 7
C7_SLMPR_ALARM_ON
N
TUPLE TO BE CHANGED:
C7_SLMPR_ALARM_ON
Y
ENTER Y TO CONFIRM, N TO REJECT or E TO EDIT.
TUPLE CHANGED