1-338 Trouble locating and clearing procedures (continued)
297-8021-544 Standard 14.02 May 2001
Running a C7BERT
(continued)
87
Determine the result of bit error injection.
Note: In the example in step 87, the number of bit errors received appears
to the right of Rx Bit Errors.
88
Subtract the result of the C7BERT recorded in step 84 from the result
obtained in step 87.
89
To determine if any requests existed for periodic reports, type
>REPORT link_no STATUS
and press Enter.
where
link_no
is the number of the link (0 to 15) that the C7BERT runs on
90
To clear the last report interval, type
>REPORT link_no OFF
and press Enter.
where
link_no
is the number of the link that the C7BERT runs on
MAP response:
91
To set the number of reports per hour, type
>REPORT link_no ON number
and press Enter.
where
link_no
is the number of the link (0 to 15) that the C7BERT runs on
If the difference
Do
is 6
step 82
is other than listed here
step 109
If the response
Do
is Link nn: Report interval al-
ready set at: mm times per hour
step 90
is Link nn: Automatic query re-
porting is not active
step 91
is other than listed here
step 109
Link nn: Automatic query reporting has been terminated