1-414 Trouble locating and clearing procedures (continued)
297-8021-544 Standard 14.02 May 2001
Testing an SPM CEM
(continued)
4
Start the CEM test by typing
>TST
and pressing the Enter key.
The following example shows a CEM screen with the test results.
CM MS IOD Net PM CCS Lns Trks Ext APPL
. . . . . . . . . .
CEM
0 Quit
2
3 Listset
4
5 Trnsl
6 Tst
7 Bsy
8 RTS
9 Offl
10 LoadMod
11
12 Next
13 Select_
14 QueryMod
15 ListAlm
16 Prot
17
18
SysB ManB OffL CBsy ISTb InSv
PM 0 0 0 0 0 1
SPM 0 0 0 0 0 1
CEM 0 0 0 0 0 1
SPM 11 CEM 0 Act INSV
Loc : Row C FrPos 4 ShPos 6 ShId 0 Slot 7
Default Load: SPMLOAD
Clock:
Input Ref: Internal Source: C Side 0 Current Mode: Acquire
14:12 >