1-600 Trouble locating and clearing procedures (continued)
297-8021-544 Standard 14.02 May 2001
TOPS MPX Token Ring LAN troubleshooting
(continued)
(Sheet 1 of 2)
Message
Number
Explanation
DFIPD040E
(cont)
Action #1:
A second message appears after message DFIPD040E. The
second message provides additional information. Take the
action the other message indicates.
Action #2:
•
To start the PC again, turn off the power. Wait 5 s. Turn
the power back on with the system disk in the A Drive.
•
To start the Ring Diagnostics again, type DFIRUN and
press ENTER.
•
If the message continues to display, run the Adapter
Diagnostics.
•
If the message continues to display, try a different System
diskette.
•
If the problem continues a problem with the adapter or the
PC is present. Remove and replace the TOPS MPX
position. Follow the common procedures. Install the
replacement TOPS MPX. Begin the test. Use the TOPS
MPX power-on self test.
DFIPD040E
Message:
Ring Diagnostic ended
Meaning: The user pressed F3 (End) or the initialization failed
and caused the Ring Diagnostic to end. When this message
displays because the user pressed F3 (End), ring status is
Adapter Closed or Wire Fault.
Action: If the user did not press F3 (End), refer to the previous
messages for more information.
Variable Data: Does not apply