Trouble locating and clearing procedures (continued) 1-241
DMS-100 Family NA100 Trouble Locating and Clearing Procedures Volume 2 of 2 LET0015 and up
Replacing an NTFX39 bulkhead splitter unit
(continued)
8
To manually busy the port, type
>BSY
and press Enter.
where
port_no
is the port identification number
9
Repeat step 8 until you manually busy all CONS ports.
10
The next action depends on any provisioned multiprotocol controller (MPC)
ports that are on the controller card.
11
To post a port for the MPC, type
>PORT port_no
and press Enter.
where
port_no
is the port identification number
Example of a IOM MAP display:
12
Determine the state of the port.
13
To display status information on current MPC conversations, type
>QCONV
and press Enter.
If the BSY command
Do
passed
step 9
failed
step 57
If provisioned MPC ports
Do
are present
step 11
are not present
step 18
If the port state
Do
is ManB
step 17
is OFFL
step 55
is other than listed here
step 13
Port 9 Unit
0
User
SYSTEM
PROTOCOL LINK
Status
Ready
X2584
COMACT ENABLED