1-224 Trouble locating and clearing procedures (continued)
297-8021-544 Standard 14.02 May 2001
Replacing a missing line card
(continued)
Replacing a missing line card
At the MAP terminal
1
To access the LTP level of the MAP display, type
>MAPCI;MTC;LNS;LTP
and press the Enter key.
2
To post the line equipment number (LEN) of the line that has faults, type
>POST L len
and press the Enter key.
where
len
is the LEN of the damaged line. Use the format ff u dd cc for frame,
unit, drawer, and circuit number.
Example input:
>POST L 00 1 00 01
Example of a MAP response
3
To locate the missing line card, type
>CKTLOC
and press the Enter key.
Example of a MAP response
4
Record the product engineering code (PEC), the PEC suffix, and the location
of the line card that has faults.
Note: The PEC appears In the MAP response in step 3. The PEC
appears under the EqPEC header. The location appears under the Site,
Flr, RPos, Bay_id, Sh, Description, and Slot headers.
5
To replace the line card that you recorded in step 4, perform the correct
procedure in
Card Replacement Procedures. Complete the procedure and
return to this point.
6
To perform a diagnostic test on the line card that you installed in step 5, type
>DIAG
and press the Enter key.
Example of a MAP response
LCC PTY RNG ...LEN.... DN STA F S LTA TE RESULT
1FR HOST 00 1 00 01 613 621 4777 IDL
Site Flr RPos Bay_id Sh Description Slot EqPEC
HOST 00 B00 LCE 00 38 LCM 00 1 00:01 6X17AC
GRD START 2DB LOSS BAL NETWORK MAN OVR SET
NO NO NON LOADED NO