1-378 Trouble locating and clearing procedures (continued)
297-8021-544 Standard 14.02 May 2001
Scheduling ISUP trunk audits
(end)
5
To enter a new ISUP trunk audit start time, type
>CHANGE 2 new_value
and press Enter.
where
new_value
is the time you want the ISUP trunk audit to start. Use the format hh
mm (hours and minutes), where hh is a number from 0 to 23 and mm
is a number from 0 to 59.
Example of a MAP response:
6
To confirm the change, type
>Y
and press Enter.
Example of a MAP response:
Note: The value will apply when the audit that uses the old value runs one
time. In other words, the next audit will run at the old time; the new time is
for the audit of the next day.
7
To quit from the table, type
>QUIT
and press Enter.
8
The procedure is complete.
requires change
step 5
CAUTION
Possible loss of service or system degradation
Ensure the new ISUP trunk audit start time is set during
off-peak hours. The audit can generate many CCS7
messages that can result in degraded service.
If the ISUP trunk audit start time
Do
TUPLE TO BE CHANGED:
CIRCUIT_QUERY_AUDIT_START_TIME
2 15
ENTER Y TO CONFIRM, N TO REJECT OR E TO EDIT.
TUPLE CHANGED