1-244 Trouble locating and clearing procedures (continued)
297-8021-544 Standard 14.02 May 2001
Replacing an NTFX39 bulkhead splitter unit
(continued)
and press Enter.
Example of MAP response:
23
Repeat steps 19 to 22 for the second DDU in the occurrence of two
provisioned DDUs.
24
The next action depends on any provisioned magnetic tape drive (MTD) ports
that are on the controller card.
25
To post a port for the MTD, type
>PORT port_no
and press Enter.
where
port_no
is the port identification number
Example of a IOM MAP display:
26
Determine the state of the port.
27
Notify all users that there will be an interruption in service for the device. Wait
until all users stop use of the device before you proceed to the next step.
28
To manually busy the port, type
>BSY
and press Enter.
Example of MAP response:
If provisioned MTD ports
Do
are on the shelf
step 25
are not on the shelf
step 30
If the port state
Do
is ManB
step 30
is OFFL
step 55
is Idle
step 28
is other than listed here
step 27
bsy
OK
Port 5 MTD
0
DevType
TapeName
User
Status
Idle