1-362 Trouble locating and clearing procedures (continued)
297-8021-544 Standard 14.02 May 2001
Running a C7BERT for high-speed links
(continued)
60
To remove the local loopback, type
>PMLOOP LOCOFF link_no
and press the Enter key.
where
link_no
is the number of the link you tested (0 to 15)
61
To remove the far-end DS-1 ESF loopback, type
>CARLOOP STOP link_no
and press the Enter key.
where
link_no
is the number of the link you tested (0 to 15)
62
Tell personnel at the intermediate point to remove the intermediate loopback.
an intermediate loopback is es-
tablished
step 62
If the response is
Do
pmloop
off
and more tests
are required
step 22
pmloop off
and you want to
exit from C7BERT
step 68
anything else
step 78
If the response is
Do
Link
n: DS-1 ESF OFF
complete
and more tests are
required
step 22
Link
n: DS-1 ESF OFF
complete
and you want to
exit C7BERT
step 68
anything else
step 78
If you want to
Do
run more tests
step 22
If
Do