Trouble locating and clearing procedures (continued) 1-535
DMS-100 Family NA100 Trouble Locating and Clearing Procedures Volume 2 of 2 LET0015 and up
TOPS MP TAMI trouble (standalone)
Clearing TAMI response failure
(continued)
Summary of Clearing TAMI response failure
Determine if
baud rate is
1200
Set baud rate to
1200
Baud rate
1200?
TAMI respond?
End
procedure
Y
N
Determine if
TAMI responds
Y
N
1
1
1
Determine if
TPC has a
power outage
TPC have
a power
outage?
Replace power
card (NT2X70)
Y
N
2
TAMI respond?
End
procedure
2
Determine if
TAMI responds
Y
N
2
Replace SBC
card (NTNX64)
Determine if
TAMI responds
TAMI respond?
Y
Replace new
SBC card with
original card
Escalate to next
level of support
End procedure
TAMI display
normal boot
messages?
Y
TAMI display
normal boot
messages?
Y
N
Refer to the appropriate
trouble locating and
clearing procedure for
the indicated trouble.
3
3
N
4
4
N
4