1-380 Trouble locating and clearing procedures (continued)
297-8021-544 Standard 14.02 May 2001
Setting up an ISUP per-call continuity test
(continued)
Summary of Setting up an ISUP per-call continuity test
Setting up an ISUP per-call continuity test
This flowchart summarizes the
procedure.
Use the instructions in the
procedure that follows this
flowchart to perform the
procedure.
Access table
TRKSGRP
Change the value
of subfield
COTREQ
End
CAUTION
Possible loss of service
Ensure that table TRKSGRP is datafilled to include the
ISUP trunks needed to perform the audit. Run the ISUP
audit. For more information on table TRKSGRP, refer to