Trouble locating and clearing procedures (continued) 1-619
DMS-100 Family NA100 Trouble Locating and Clearing Procedures Volume 2 of 2 LET0015 and up
TOPS MPX Token Ring LAN troubleshooting
(continued)
Message
Number
Explanation
DFIPD214E
Message:
Unable to close ring adapter
Meaning: This adapter did not respond correctly to the attempt
of the Ring Diagnostic to close the adapter.
Action: Run the Adapter Diagnostics on this adapter. If the
diagnostics indicate that the adapter functions correctly and the
message repeats, perform the following function:
1.
Verify that the indicated adapter is installed and that the
switches are set correctly. Correct any errors found.
2.
Start the PC again.
3.
Start the Ring Diagnostic.
4.
If the same message occurs, try a different System
Diskette.
5.
If the preceding action does not correct the problem,
record the variable data. Perform manual troubleshooting
procedures.
Variable Data:
09/21/91 13:06:56 DFIPD213E Ring adapter microcode failed
––––––> 002604
Adapter Number
Return Code
Command Code Bring Up Error
09/21/91 13:06:56 DFIPD213E Ring adapter microcode failed
––––––> FF000001
Indicator Flag (PC-detected error)
Adapter Number
Error Reason Code