Trouble locating and clearing procedures (continued) 1-359
DMS-100 Family NA100 Trouble Locating and Clearing Procedures Volume 2 of 2 LET0015 and up
Running a C7BERT for high-speed links
(continued)
49
Record the number of Rx bit errors.
Note: In the example in step 48, the number of bit errors received appears
to the right of Rx bit errors.
50
To inject bit errors, type
>INJERR link_no
and press the Enter key.
where
link_no
is the number of the link you tested in step 39
Example of a MAP response:
51
To display the result of injecting bit errors, type
>QUERY link_no PR
and press the Enter key.
where
link_no
is the number of the link that you want to test (0 to 15)
Example of a MAP response:
If the response is
Do
Link 1: INJECT ERROR
completed
step 51
Link n:Failed - C7BERT is not
active on this link
step 39
anything else
step 78
If the response is
Do
a display of test statistics
step 52
anything else
step 78
injerr 1
Link 1: C7BERT query
Run Time : 1134 Err Free Secs: 1133
Tx Frames : 32568 Rx Sync Errs : 0
Rx Frames : 32570 Rx Bad Frames: 1
Rx Bit Errors: 1 Rx Bits : 66670792
Bit Err Rate : 1 x 10– 8