1-636 Trouble locating and clearing procedures (continued)
297-8021-544 Standard 14.02 May 2001
Troubleshooting a customer-reported failure
No PM alarms
(continued)
15
Determine the state of each channel.
16
Select a manual-busy channel to return to service.
17
To post the channel, type
>POST chan_no
and press Enter.
where
chan_no
is the number of the channel that will return to service
18
To return the channel to service, type
>RTS
and press Enter.
19
Repeat steps 17 to 18 for each manual-busy channel.
Go to step 20.
20
Determine if the channels are in service.
21
Perform the correct procedure to clear the alarm.
Alarm and Performance
Monitoring Procedures describe alarm clearing procedures.
CARRIER Alarm BER ES SES UAS
InSv <–9. 0 0 211
CHANNEL 1
N
CHANNEL 1 ( 24 x DS0)
InSv /NoLMI
If the channel state
Do
is
ManB
step 16
is any other item, and the cus-
tomer uses Datapath
step 22
is any other item, and the cus-
tomer uses DDS
step 23
If one or more channels
Do
are dot (.) (in service)
step 24
are any other items
step 21