1-392 Trouble locating and clearing procedures (continued)
297-8021-544 Standard 14.02 May 2001
Setting up the signaling link marginal performance report
(continued)
41
To specify standard log format, type
>STD
and press Enter.
Example of a MAP response:
42
To specify that message priority is not important, type
>N
and press Enter.
Example of a MAP response:
43
To specify that a guaranteed device is not necessary, type
>N
and press Enter.
Example of a MAP response:
44
To confirm the changes, type
>Y
and press Enter.
45
To quit from table LOGDEV, type
>QUIT
and press Enter.
46
To access the LOGUTIL software, type
>LOGUTIL
and press Enter.
47
To start to print log CCS198 on the printer, type
>STARTDEV printer_name
and press Enter.
where
printer_name
is the printer you specified in table LOGDEV in step 38 or step 39
48
To quit from the LOGUTIL software, type
>QUIT
and press Enter.
PRIORITY:
GUAR:
TUPLE TO BE ADDED:
STD N
N
RP061 NIL (1)