1-340 Trouble locating and clearing procedures (continued)
297-8021-544 Standard 14.02 May 2001
Running a C7BERT
(continued)
95
Remove the manual loopback across network elements.
96
The next step depends on the instructions received from the next level of
support.
97
To remove the link fault sectionalization, type
>LFSLOOP STOP link_no
and press Enter.
where
link_no
is the number of the tested link (0 to 15)
98
To quit the C7BERT level of the MAP display, type
>QUIT
and press Enter.
99
To activate the link that the C7BERT ran on, type
>ACT link_no
and press Enter.
the link stops on an NT9X77AA or
NT9X78BA/CA/DA/DB card, and you just ran a link
fault sectionalization. If instructions required you to
perform more tests
step 70
link does not stop on an NT9X77AA or
NT9X78BA/CA/DA/DB card
step 95
other than listed here
step 110
If
Do
instructions require you to return
the link to service
step 98
instructions require you to per-
form more tests
step 73
other than listed here
step 110
If the response
Do
is LFSLoop stop n
is Link n: LFS OFF complete
step 98
is other than listed here
step 109
If
Do