1-476 Trouble locating and clearing procedures (continued)
297-8021-544 Standard 14.02 May 2001
TOPS MP Operator complaint (standalone)
Clearing position failure - cannot reboot TPC
(continued)
2
To set the TPC again, lower and lift the single-board computer (SBC) reset
switch.
3
To determine if the TPC has a power outage, check the frame fail light on the
frame supervisory panel (FSP).
1 meg of memory
step 20
any other message
Refer to the correct locating and
clear trouble procedure for the
indicated trouble.
If
Do
the TPC reboots
step 25
the VDU displays an asterisk (*)
step 24
the VDU displays any other
message
Refer to the correct locating and
clear trouble procedure for the
indicated trouble.
If the error message is
Do
1–3
25–27
Power
switch
6
SBC reset switch
21–23
17–19
Disk drives and switch locations on the TPC