1-356 Trouble locating and clearing procedures (continued)
297-8021-544 Standard 14.02 May 2001
Running a C7BERT for high-speed links
(continued)
link_no
is the number of the link being tested (0 to 15)
Example of a MAP response:
41
Determine if any Tx frames were transmitted.
Note: The number of frames transmitted appears to the right of the Tx
Frames header of the MAP display. In the example in step 40, the number
of frames transmitted is 19 016.
42
The test is running correctly.
Test results generate when:
•
the periodic reporting function is active
•
operating company personnel stop the test manually
•
the test stops automatically at a pre-set time
Note: If the switch restarts when an HSL C7BERT is running on a link, the
test stops automatically. The test also stops automatically if the HLIU
associated with the link fails.
If the response is
Do
a display of HSL C7BERT sta-
tistics
step 41
anything else
step 78
If
Do
any Tx frames were transmitted
step 42
no Tx frames were transmitted
step 78
If
Do
you want to request periodic re-
ports
step 54
you want to stop the test manual-
ly
step 58
query 1 pr
Link 1: C7BERT query
Run Time : 662 Err Free Secs: 662
Tx Frames : 19016 Rx Sync Errs : 0
Rx Frames : 19019 Rx Bad Frames: 0
Rx Bit Errors: 0 Rx Bits : 38931896
Bit Err Rate : 0 x 10–15