Trouble locating and clearing procedures (continued) 1-319
DMS-100 Family NA100 Trouble Locating and Clearing Procedures Volume 2 of 2 LET0015 and up
Running a C7BERT
(continued)
22
PM loop functionality is not available on your switch.
23
To stop the C7BERT that exists, type
>STOP link_no
and press Enter.
where
link_no
is the number of the link that you entered in PMLOOP command
Note: The STOP command overrides a preset stop time without warning.
24
Apply manual loopbacks to the network elements that you will test.
25
To determine if a set stop time exists, type
>SETSTOP link_no STATUS
and press Enter.
where
link_no
is the number of the link (0 to 15) that the C7BERT runs on
26
To clear the stop time, type
>SETSTOP link_no CLEAR
and press Enter.
is other than listed here
step 66
If
Do
you want to run a C7BERT
step 24
other than listed here
step 66
If the response
Do
is Link 1: C7BERT stopped
repeat PMLOOP
is other than listed here
step 66
If the response
Do
is Link nn: Stop time set at:
is time
step 26
is Link nn: No stop time has
been set
step 27
is other than listed here
step 66
If the response
Do