1-334 Trouble locating and clearing procedures (continued)
297-8021-544 Standard 14.02 May 2001
Running a C7BERT
(continued)
link_no
is the number of the link that the C7BERT runs on
76
To set the stop time that is new, type
>SETSTOP link_no SET day hours minutes
and press Enter.
where
link_no
is the number of the link (0 to 15) that the C7BERT runs on
day
is the day you want the test to stop automatically (MON, TUE, WED,
THU, FRI, SAT, or SUN)
hours
is the hour you want the test to stop automatically (0 to 23)
minutes
is the minute you want the test to stop automatically (00 to 59)
Example input:
>SETSTOP 3 SET MON 10 30
Note: The example entry sets the stop time for link 3 on every Monday at
10:30 a.m.
77
Determine if the stop time is correct.
78
Wait until the C7BERT stops.
Go to step 94.
If the response
Do
is Stop time cleared
step 76
is other than listed here
step 109
If the response
Do
is Link nn: Stop time set at:
is 19xx/yy/zz
is hh:mm:00.000 ddd
step 77
is other than listed here
step 109
If the stop time
Do
is correct
step 78
is wrong
step 75