1-330 Trouble locating and clearing procedures (continued)
297-8021-544 Standard 14.02 May 2001
Running a C7BERT
(continued)
63
Tell the person at the far-end office to activate the link. To activate the link
from your end, type
>ACT link_no
and press Enter.
where
link_no
is the number of the link you activated in step 56
64
To return the link to service, type
>RTS link_no
and press Enter.
where
link_no
is the number of the link you activated in step 56
65
To unhibit the link, type
>UINH link_no
and press Enter.
where
link_no
is the number of the link you activated in step 56
66
For additional help, contact the next level of support.
67
If the ACT command
Do
passed
step 64
failed
step 66
If the RTS command
Do
passed
step 65
failed
step 66
If the UINH command
Do
passed
step 110
failed
step 66
ATTENTION
To run link fault sectionalization (LFS) the SOC option TEL0007 must have the RTU
set to "Y" and the state set to "on".