Trouble locating and clearing procedures (continued) 1-381
DMS-100 Family NA100 Trouble Locating and Clearing Procedures Volume 2 of 2 LET0015 and up
Setting up an ISUP per-call continuity test
(continued)
At the MAP terminal
1
To access table TRKSGRP, type
>TABLE TRKSGRP
and press Enter.
2
To position on the trunk subgroup that you want to install the ISUP per-call
continuity test, type
>POSITION subgroup_name subgroup_no
and press Enter.
where
subgroup_name
is the common-language location identifier (CLLI) name of the
subgroup
subgroup_no
is the number of the subgroup (0 or 1)
Example of a MAP response:
3
To indicate that you want to change the tuple, type
>CHANGE
and press Enter.
Example of a MAP response:
4
Press Enter until the MAP response is COTREQ.
Example of a MAP response:
5
To specify the percentage of calls that you want performed for the per-call
continuity test, type
>new_value
and press Enter.
where
new_value
is the percentage of calls on this trunk that the ISUPper-call continuity
test will perform (0 to 100)
6
Press Enter until the MAP response is OPTION.
MAP response:
BRABRAEOIS 0
DS1SIG
C7UP OG N N UNEQ NONE Q764 THRH 100 DMSNODE NIL $
CARDCODE:
DS1SIG
COTREQ: 0
OPTION: