1-510 Trouble locating and clearing procedures (continued)
297-8021-544 Standard 14.02 May 2001
TOPS MP Operator complaint (standalone)
Clearing voice communication path trouble
(continued)
11
Replace the conference circuit card. Refer to
Card Replacement Procedures
and return to this step.
12
To test the posted CF3P circuit again, type:
>TST
and press the Enter key.
13
Perform the common procedure
Removing an MP position from service
(standalone).
At the TAMI
14
To access the Diagnostics screen from the TAMI main menu, type:
>5
and press the Enter key.
Example of a TAMI response
15
To run the position component diagnostics (TCD) test, type:
>POSDIAG n TCD
and press the Enter key.
where
n
is the MP position number (0,1, 2, or 3)
If test
Do
passes
step 17
fails
step 13
Enter TPC Diagnostics command: