1-84 Trouble locating and clearing procedures (continued)
297-8021-544 Standard 14.02 May 2001
Replacing a 3.5 in. disk drive unit
NTFX32BA
(continued)
Replacing a 3.5 in. disk drive unit NTFX32BA
At the MAP terminal
1
Obtain the following items:
•
replacement DDU
•
flat-blade screwdriver with 1/4-in. (3-mm) blade
Obtain a shipping carton for the replaced DDUs. When possible, use the
carton of the new DDUs.
To access the IOD level of the MAP display, type
>MAPCI;MTC;IOD
and press Enter.
Example of a MAP display:
2
To post the input/output module (IOM) controller for the replaced DDU, type
>IOC ioc_no
and press Enter.
where
ioc_no
is the number of the affected IOM
Example of a IOM MAP display:
CAUTION
Loss of service
Disk allocation is difficult and dangerous errors are possible.
Contact the next level of support before you perform this
procedure.
IOD
IOC 0 1 2 3
STAT . . . S
DIRP: SMDR B XFER: . SLM : . NPO: . NX25: .
MLP : . DPPP: . DPPU: . SCAI :
IOC PORT 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17
(IOM) STAT . . . – . . – – – . – – – – – – – –
0
TYPE C C C C M
M
S S
O O O O T
P
C C
N N N N D
C
S S