Trouble locating and clearing procedures (continued) 1-345
DMS-100 Family NA100 Trouble Locating and Clearing Procedures Volume 2 of 2 LET0015 and up
Running a C7BERT for high-speed links
(continued)
Running a C7BERT for high-speed links
At the MAP terminal
1
Contact the next level of support to obtain the following information:
•
how to stop the test (manually or automatically)
•
if periodic reports are required and how many times each hour (1 to 12)
2
If you want to perform a remote loopback, inform personnel at the far-end
office that
•
you want to busy and return the link to service
•
they must busy and return the link to service at their end
3
To enter the C7LKSET level of the MAP display, type
>MAPCI;MTC;CCS;CCS7;C7LKSET
and press the Enter key.
Example of a MAP response:
4
To post the linkset that includes the link that you want to test type
>POST C linkset_name
and press the Enter key.
where
linkset_name
is the name of the linkset (as defined in table C7LKSET)
Example of a MAP response:
CAUTION
Risk of service interruption
The following procedure takes a CCS7 link out of service.
Before proceeding, consult your next level of support to
ensure network impact is minimized.
Traf Sync
Link
LK Stat Stat Resource Stat Physical Access Stat
Action
Traf Sync
Link
LK Stat Stat Resource Stat Physical Access Stat Action
0
OffL DAct DLIU 12 OffL DS1
1
SysB DAct DLIU 13 InSv DS1
Size of Posted Set = 2