Trouble locating and clearing procedures (continued) 1-353
DMS-100 Family NA100 Trouble Locating and Clearing Procedures Volume 2 of 2 LET0015 and up
Running a C7BERT for high-speed links
(continued)
28
To post the HLIU, type
>POST HLIU dliu_no
and press the Enter key.
29
To clear the loopback state, type
>LOOPBK C
and press the Enter key.
30
To enter the C7LKSET level of the MAP display, type
>MAPCI;MTC;CCS;CCS7;C7LKSET
and press the Enter key.
31
To enter the C7BERT level of the MAP display, type
>C7BERT
and press the Enter key.
32
To stop the existing HSL C7BERT, type
>STOP link_no
and press the Enter key.
where
link_no
is the number of the link you entered in step 23 or 25
Note: The STOP command overrides any preset stop time without
warning.
33
Contact personnel at the far end to confirm that the far-end signaling terminal
is able to receive control codes.
If the response is
Do
LoopBk passed
step 30
anything else
step 78
If you want to
Do
activate a local loopback
step 23
activate a remote loopback
step 25
If you want to
Do
activate a local loopback
step 23
activate a remote loopback
step 25