Trouble locating and clearing procedures (continued) 1-43
DMS-100 Family NA100 Trouble Locating and Clearing Procedures Volume 2 of 2 LET0015 and up
Repairing FAN faults on an LCEI frame;
cooling unit replacement
(continued)
At the front of the frame
24
Replace the four 5/16-inch bolts that secure the cooling unit side brackets
(two per side) that you removed in step 11. Secure the brackets in position.
At the back of the frame
25
At the back of the cooling unit, reconnect the power plug or power leads
disconnected in step 19.
At the PDC
26
Reinstall the two fuses (cooling unit 0 or 1) removed in step 18.
At the front of the frame
27
At the front of the cooling unit, reinstall the five 0.5-amp fan fuses (numbered
1 through 5) removed in step 17.
28
Check the FAN FAIL lamp on the front panel of the cooling unit.
29
Reinstall the side trim and secure with the top and bottom screws removed in
step 10.
30
Go to step 52.
At the front of the frame
31
Pull the cooling unit part way out of the frame. The power cord can be too
short to gain access to the front three fans. If the cord is too short, repair the
unit on a bench top.
DANGER
Risk of personal injury
Electricity can arc when you replace fan unit fuses. Wear eye
protection.
If the FAN FAIL lamp
Do
is off
step 29
is on
step 46
If the power cord
Do
is too short
step 17
is long enough
step 32