Trouble locating and clearing procedures (continued) 1-327
DMS-100 Family NA100 Trouble Locating and Clearing Procedures Volume 2 of 2 LET0015 and up
Running a C7BERT
(continued)
49
To deactivate a remote loopback, type
>PMLOOP RMTOFF link_no
and press Enter.
where
link_no
is the number of the link you tested in step 18
50
To determine if a set stop time exists, type
>SETSTOP link_no STATUS
and press Enter.
where
link_no
is the number of the link (0 to 15) that the C7BERT runs on
51
To clear the stop time, type
>SETSTOP link_no CLEAR
and press Enter.
where
link_no
is the number of the link that the C7BERT runs on
52
To set the stop time that is new, type
>SETSTOP link_no SET day hours minutes
and press Enter.
If the response
Do
is
pmloop off 1
Link
1: Loopback Re-
mote off completed
step 55
is other than listed here
step 66
If the response
Do
is Link nn: Stop time set at:is
time
step 51
is Link nn: No set stop time
step 52
is other than listed here
step 66
If the response
Do
is Stop time cleared
step 52
is other than listed here
step 66