1-480 Trouble locating and clearing procedures (continued)
297-8021-544 Standard 14.02 May 2001
TOPS MP Operator complaint (standalone)
Clearing position failure - cannot reboot TPC
(continued)
13
Determine if the hard disk drive light flashes.
14
Examine the VDU display.
15
Replace the hard disk drive. Refer to
Card Replacement Procedures and
return to this step.
16
Replace the new hard disk drive with the original hard disk drive removed in
step 15. Refer to
Card Replacement Procedures and return to step 18.
If the hard disk drive light
Do
flashes
step 14
does not flash
step 15
If
Do
autobooting... continues to ap-
pear
step 18
the TPC reboots
step 25
any other message appears
Refer to the correct locating and
clearing trouble procedure for
the indicated trouble.
If
Do
autobooting... continues to ap-
pear
step 16
autobooting... continues to ap-
pear and the original hard disk
drive is installed again
step 17
the TPC reboots
step 25
any other message appears
Refer to the correct locating and
clearing trouble procedure for
the indicated trouble.