1-318 Trouble locating and clearing procedures (continued)
297-8021-544 Standard 14.02 May 2001
Running a C7BERT
(continued)
20
Before activating a remote loopback, access the C7BERT level of the MAP
display at the far end office, typimg
>C7BERT
and pressing Enter.
21
To activate a remote loopback, at the far end office, type
>PMLOOP RMTON link_no
and press Enter.
where
link_no
is the number of the link you want to test (0 to 15)
If the response
Do
is
This command
is not
implemented
step 22
is
Link
1:
Failed
-
C7BERT already active
on this link
step 23
is
Link 1: Loopback Re-
mote On completed
step 30
is
Link 1: Failed - PM-
LOOP
<Local>
is
al-
ready active
step 48
is
Link 1: Failed - PM-
LOOP
<Remote>
is
al-
ready active
step 49
is
Failed
—
Cannot
seize trunk
Check the corresponding DTC,
and retry the remote loopback.
is
Failed —
Cannot in-
stall
NIU connection
(NIU-LIU)
Check the corresponding NIU,
and retry the remote loopback.
is
Link 1: Loopback Re-
mote
On
completed.
WARNING:
In DTE mode,
the V.35 clock must be
present for C7BERT to
pass
step 66