Trouble locating and clearing procedures (continued) 1-361
DMS-100 Family NA100 Trouble Locating and Clearing Procedures Volume 2 of 2 LET0015 and up
Running a C7BERT for high-speed links
(continued)
link_no
is the number of the link (0 to 15) on which the HSL C7BERT is running
number
is the number of reports per hour (1 to 12)
Example input:
>REPORT 1 ON 6
57
Determine if the report interval is correct.
58
To stop the HSL C7BERT, type
>STOP link_no
and press the Enter key.
where
link_no
is the number of the link (0 to 15) on which the HSL C7BERT is running
Note: The STOP command overrides any preset stop time without
warning.
59
Give the results to the personnel responsible for the next level of support.
Your next step depends on the instructions received from your next level of
support.
If the response is
Do
Link nn: Report interval set at:
nn times per hour
step 57
anything else
step 78
If the interval is
Do
correct
step 42
not correct
step 55
If the response is
Do
Link 1: C7BERT stopped
step 59
anything else
step 78
If
Do
the far-end DS-1 loopback is es-
tablished
step 61
the local loopback is established
step 60