background image

 

 
 
 
 
 
 

 

 

     Vicon part number 8009-8164-30-00   

  Rev 607 Section 10 

 

                                                                     

XX164-30

  

 
 
 
 
 
 

MODEL VF-220 SERIES  

TWO-CHANNEL FIBER-OPTIC VIDEO 

TRANSMISSION SYSTEM

  

 
 
 
 
 
 
 
 
 
 
 
 
 
 

  

  

 

 

 
Copyright © 2007 Vicon Industries Inc. All rights reserved. 
Product specifications subject to change without notice. 
Vicon and its logo are registered trademarks of Vicon Industries Inc. 
 
 

VICON INDUSTRIES INC., 89 ARKAY DRIVE, HAUPPAUGE, NEW YORK 11788 

TEL: 631-952-CCTV (2288)  FAX: 631-951-CCTV (2288)  TOLL FREE: 800-645-9116 

24-Hour Technical Support: 800-34-VICON (800-348-4266) 

UK: 44/(0) 1489-566300  WEB: www.vicon-cctv.com 

Summary of Contents for VF-220 Series

Page 1: ... All rights reserved Product specifications subject to change without notice Vicon and its logo are registered trademarks of Vicon Industries Inc VICON INDUSTRIES INC 89 ARKAY DRIVE HAUPPAUGE NEW YORK 11788 TEL 631 952 CCTV 2288 FAX 631 951 CCTV 2288 TOLL FREE 800 645 9116 24 Hour Technical Support 800 34 VICON 800 348 4266 UK 44 0 1489 566300 WEB www vicon cctv com ...

Page 2: ...XX164 20 VF 220 Transmission System FCC Notice 2 ...

Page 3: ...ermined by turning equipment off and on the user is encouraged to try and correct the interference by one or more of the following measures Reorient the receiving antenna Relocate the equipment with respect to the receiver Relocate the equipment away from the receiver Plug the equipment into a different electrical outlet so that the equipment and receiver are on different branch circuits If necess...

Page 4: ...nit 13 Outdoor Cable Grounding Use only grounded outdoor cables to protect against voltage surges and static charges Section 810 of the National Electrical Code ANSI NFPA 70 1984 provides information on proper grounding of the lead in wire to an antenna discharge unit size of grounding conductors and the requirements of grounding electrodes 14 Lightning Disconnect the product from its power source...

Page 5: ...ransmitter accepts up to two video inputs Each video input modulates a separate FM carrier frequency to allow the total of four video signals to be combined onto one fiber The VF 220 Series is designed to operate over an optical loss budget range of 0 to 12 dB when used on 62 5 μ m multimode fiber A maximum distance of 5 km can be achieved as long as the overall fiber bandwidth maintains a minimum...

Page 6: ... card cage Please refer to the VF SR 20 2 and VF PSR 2 instruction manual XX164 60 for further details Power Connection On standalone units power is supplied to the unit via a three pin Phoenix connector The ground wire from the center tap supply must be connected to the center pin of the Phoenix connector When installed properly the nominal voltage measured from the center pin to either of the ou...

Page 7: ...XX164 20 VF 220 Transmission System Power Connection 5 VF 220T Transmitter VF 220R Receiver ...

Page 8: ...6 Power Connection XX164 20 VF 220 Transmission System VF 220TR Rack Mount Transmitter VF 220RR Rack Mount Receiver ...

Page 9: ...cted Power A green LED indicator monitors the internal voltages created within the unit Power status associated with this LED is summarized below Power Indicator Power Status Green Voltage Present Off Check Power Supply Status Indicators Rack Mount Units The VF 220TR transmitter and VF 220RR receiver provide the following LED status indicators to aid in installation and troubleshooting VLI 1 and V...

Page 10: ...smission System Power VF 220R A green LED indicator monitors the internal voltages created within the receiver Power status associated with this LED is summarized below Power Indicator Power Status Green Voltage Present Off Check Power Supply ...

Page 11: ... in Europe contact Vicon Industries Ltd Brunel Way Fareham PO15 5TX United Kingdom Phone 44 0 1489 566300 Fax 44 0 1489 566322 2 Attach a sheet of paper to the unit with the following information a Name and address of the company returning the unit b Name of the Vicon employee who issued the R A c R A number d Brief description of the installation e Complete description of the problem and circumst...

Page 12: ...t 2 rack slots Standalone 1 4 lb 0 6 kg Rack Mount 0 7 lb 0 3 kg Aluminum Standalone Silver Rack Mount Black paint No 8 3 mm hardware 4 places Standalone Height 3 5 in 89 mm Width 8 3 in 211 mm Depth 14 5 in 368 mm Rack Mount Height 3 1 in 79 mm Width 7 0 in 178 mm Depth 10 2 in 259 mm Standalone 2 9 lb 1 3 kg Rack Mount 1 1 lb 0 5 kg Standalone 0 24 ft 3 0 007 m 3 Rack Mount 0 13 ft 3 0 004 m 3 4...

Page 13: ...t which may have been tampered with altered misused or been subject to unauthorized repair Software supplied either separately or in hardware is furnished on an As Is basis Vicon does not warrant that such software shall be error bug free Software support via telephone if provided at no cost may be discontinued at any time without notice at Vicon s sole discretion Vicon reserves the right to make ...

Page 14: ...rs Brunel Way Fareham PO15 5TX United Kingdom 44 0 1489 566300 Fax 44 0 1489 566322 Germany vin videotronic infosystems gmbh Lahnstrasse 1 D 24539 Neumuenster Phone 49 0 4321 8790 Fax 49 0 4321 879 47 Far East Office Unit 5 17 F Metropole Square 2 On Yiu Street Shatin New Territories Hong Kong 852 2145 7118 Fax 852 2145 7117 Internet Address www vicon cctv com ...

Reviews: